Hi guys. Please check my previous post for any background questions, I don’t have it in me to go over everything again.

Long story short, I was having issues with clogging that were being caused by my hotend not reaching the reported temp. After a few days of troubleshooting and diagnosing the motherboard and Klipper settings, I gave up and decided the motherboard was faulty (even though I could not perform any tests to determine in) and bought an SKR mini. I got that all set up, and the printer has been working flawlessly since then.

Until now.

Same exact problem; one print goes perfectly fine, next print, failing to extrude by the 4th layer. I removed the clog, restarted the print, now can’t even extrude the priming line. Fearing the worst, I disassemble the hotend, try hand feeding filament, and once again I am unable to push more than a few centimeters through before it gets clogged up. A probe thermometer reads ~160C while Klipper reports 200C.

What could possibly be happening here? The board is an aftermarket replacement from a completely different company, so I doubt it’s a recurring manufacturer defect, but I have no idea what else can be causing this.

At this point I’ve spent so much time and money trying to fix this printer that I could almost buy a new one, but at this point I’m not convinced even that would solve the problem.

  • papalonian@lemmy.worldOP
    link
    fedilink
    English
    arrow-up
    1
    ·
    1 month ago

    Thermistor swap was done a few times on the old board when the same issue was happening. I had 3 of them that I was swapping between.

    Currently in there is a pretty nice thermistor that, rather than using a set screen to keep it in place, is actually built in to the end of a set screw; it’s effectively impossible to damage it. Unfortunately, it’s a known-good resistor, my problem lies elsewhere.

    • morbidcactus
      link
      fedilink
      English
      arrow-up
      1
      ·
      1 month ago

      Wow yeah, that’s even more annoying then. Last ditch thing to me would be to check the resistance across th0 and compare to thb, I got ~6.28 kohms on both checking a spare board, just super strange this happened so suddenly.

      • papalonian@lemmy.worldOP
        link
        fedilink
        English
        arrow-up
        1
        ·
        1 month ago

        Good call on checking that resistance, didn’t think of that before.

        Even more frustrating is it happening twice across two different boards!