Lately I’ve had some obviously inaccurate measurements from my Timemore Black Mirror scale. That would happen occasionally but not always. I was charging it today and as luck would have it, I was sitting beside it. I typically charge it unattended. I noticed that it took a very long time to charge and multiple times it seemed to restart charging. I grabbed it to check the cable and noticed it was quite warm in one spot. I though - that’s alright, it’s likely where the battery cell is, it’s charging, lithium cells get warm during charging. Later I took it off the charger and while handling it I examined the hot spot a bit more. I noticed that when I squeezed the scale at that corner, the top plate wouldn’t sink towards the bottom as it does in the other corners. A few mental calculations later I figured this could be a swollen cell that has grown so large that it impacts the plates and doesn’t let them come together as they do normally. I took it apart. Lo and behold this spicy pillow:

The marking on it means it’s supposed to be 8mm thick. It’s currently closer to 12.5mm. Removing the battery allowed the two plates to come together in all corners as normal. That confirmed the hypothesis. Further, the reason why it only occasionally impacted the measurements is likely due to the weight of the cup I was using. When using a lighter cup, the total weight would be lower than needed to get the two plate to touch the battery and produce inaccurate measurement.

I ordered this as a replacement. It fits the dimensions and it’s got some safety certification.

To check if your scale is a fire hazard, squeeze this corner:

Normal squeeze action looks like this. Unfortunately I didn’t record a video prior to removing the battery.

If it the two plates come together as the do in the other corners, you’re probably okay. If the plates don’t come nearly as close, you’ve got an unlit petard in your hands.

  • leds@feddit.dk
    link
    fedilink
    arrow-up
    12
    ·
    18 hours ago

    Yeah my nobrand cheap coffee scale also has a tiny spicy pillow, I really should replace it.

    • hinterlufer@lemmy.world
      link
      fedilink
      arrow-up
      13
      ·
      16 hours ago

      You really should. Probably right now.

      I also never understood why we are moving away from alkaline/NiMH for low power devices such as scales. My cheapo scale takes 2 AAA cells which I have to charge like once a year. They are safer and designed to be replaced. And probably also cheaper in production.

      • JustEnoughDucks@feddit.nl
        link
        fedilink
        arrow-up
        3
        ·
        edit-2
        13 hours ago

        Ease of electronics.

        It is more expensive and bulkier using those cells because you need boost converters instead of dirt cheap linear regulators to put a modern 3.3V MCU in there. With how cheap lithium cells are (and that they are rechargeable) nowadays, the power converters + the mechanical AAA housing is often more expensive than a lithium cell + charger

        Hopefully we will switch over to sodium ion in the coming 5 years or so which are rechargeable, cheaper materials, higher charge cycle counts, and completely safe at the cost of also needing a boost converter. Maybe we will even start to shift more towards 1.8V MCUs. Sodium ion is better in nearly every way than alkaline while just having bad capacity compared to Li-ion.

        • lightrushOP
          link
          fedilink
          arrow-up
          1
          ·
          10 hours ago

          Yeah, if the cells are standard, available and easy to replace and safe if abandoned, it’s not a huge deal replacing them every few years.

    • lightrushOP
      link
      fedilink
      arrow-up
      8
      arrow-down
      1
      ·
      edit-2
      17 hours ago

      TBH, this is a risk for all “value” devices that don’t have to pass NA/EU electrical certification. No cert means the cell can be whatever part was cheap and alright enough. Longer term reliability without specific testing isn’t obvious. Every now and then I fall into the rabbit hole of trying to remember all the different devices with potentially questionable cells. The occasion today is likely to trigger another sweep.

      • halfapage@lemmy.world
        link
        fedilink
        English
        arrow-up
        4
        ·
        edit-2
        17 hours ago

        This is a risk for all li-pol batteries. Risk in value devices is of course higher.

        It can be caused by many things, but unfortunately in a large part the design principles and chemistry inside those batteries are to blame. Those things are are kind of bound to happen until somebody comes up with a better solution.

        And yes, you should monitor the batteries you own as parts of devices. If you don’t use it for extended period of time, store it safely. Don’t toss them somewhere you’d forget it where they could cause a fire of they self ignited.

      • Hamartiogonic@sopuli.xyz
        link
        fedilink
        arrow-up
        2
        ·
        16 hours ago

        The cable that came with my cheap scale is borderline e-waste. The resistance of that abomination is many times higher than with any USB cable I’ve ever measured, so it’s pretty clear which corners were cut in production. I wonder how bad the battery is though… Better be careful when charging it.

      • lightrushOP
        link
        fedilink
        arrow-up
        1
        ·
        edit-2
        10 hours ago

        An army surplus ammo can with its gasket removed.