cross-posted from: https://lemmy.ca/post/23884006

Link to full text study:

https://www.thelancet.com/journals/landig/article/PIIS2589-7500(24)00094-3/fulltext

Background Cooling towers containing Legionella spp are a high-risk source of Legionnaires’ disease outbreaks. Manually locating cooling towers from aerial imagery during outbreak investigations requires expertise, is labour intensive, and can be prone to errors. We aimed to train a deep learning computer vision model to automatically detect cooling towers that are aerially visible.

Methods Between Jan 1 and 31, 2021, we extracted satellite view images of Philadelphia (PN, USA) and New York state (NY, USA) from Google Maps and annotated cooling towers to create training datasets. We augmented training data with synthetic data and model-assisted labelling of additional cities. Using 2051 images containing 7292 cooling towers, we trained a two-stage model using YOLOv5, a model that detects objects in images, and EfficientNet-b5, a model that classifies images. We assessed the primary outcomes of sensitivity and positive predictive value (PPV) of the model against manual labelling on test datasets of 548 images, including from two cities not seen in training (Boston [MA, USA] and Athens [GA, USA]). We compared the search speed of the model with that of manual searching by four epidemiologists.

  • OtterOPA
    link
    fedilink
    English
    arrow-up
    3
    ·
    5 months ago

    That’s part of why I clicked the article, I was confused if I read it correctly