As you might be aware BambuLab issued a recall for the BambuLab A1 3d-printer. In particular, the issue is the mains-voltage (230V AC) heat bed cable.

As a resolution, they offer two solutions:

  1. Ship the entire printer back to them and receive a replacement printer.
  2. They mail a new cable and you install it.

What BambuLab doesn’t mention at all is the test according to EN 50678 (Verification of the effectiveness of protective measures of electrical equipment after repair). Unless you can perform this test I would recommend choosing the printer replacement.

  • cecilkorik
    link
    fedilink
    English
    arrow-up
    4
    ·
    10 months ago

    DC adds an extra layer of isolation if something goes wrong, and an extra place for it to fail safely in a nicely enclosed metal box. It takes a really catastrophic failure for a 28A DC power supply to go much beyond 28A for very long. A mains supply can do it all day long unless there’s some other form of protection like a fuse or isolation transformer.

    • EmilieEvans@lemmy.mlOP
      link
      fedilink
      English
      arrow-up
      5
      ·
      10 months ago

      From my experience contact failure is the most common cause of failures: 3A can go wrong. 28A is a bad day.

      Similarly, a fuse won’t protect at all against contact failures (the fuse doesn’t care as the current doesn’t rise) and active monitoring isn’t found outside the industrial applications.

      To provide some numbers on cables: A German company specifies their drag chain cables for 10 mio. cycles and they maintain a test lab to verify it and get the data required for the lifetime calculator. QC is excellent as well. In other words: Very unlikely the cable will be the issue. Assuming you see it as an issue there is always the option to use double insulated cables (no short or exposed conductors; designed to fail open). A TPE insulation rubbing through is also highly unlikely.

      The contact points (connectors) are challenging. These conductors need to connect to another conductor, PCB or ceramic element so that it can withstand the vibration, acceleration, corrosion, etc. The higher the current is the lower the contact resistance needs to be the more it is susceptible to small changes.

      Another problem with high currents is their electromagnetic radiation.