• nEODiE@lemmy.world
      link
      fedilink
      arrow-up
      7
      arrow-down
      1
      ·
      11 months ago

      They’d want to cheap, really cheap

      With a calendar lifespan of 10 years (at 25°C) and up to 4,000 cycles at 35°C, the indoor-only battery

      Not many places in Australia where 25° is a reasonable metric to go by. Given the rate at which anything battery powered is catching on fire, I think I’ll pass sticking one of these in my house

      • w2qw@aussie.zone
        link
        fedilink
        arrow-up
        5
        ·
        11 months ago

        The working temperature says -20C to 55C. That just seems to be what they’ve quoted the lifespan under.

    • No1@aussie.zone
      link
      fedilink
      arrow-up
      3
      arrow-down
      9
      ·
      edit-2
      11 months ago

      Shhhhhhh!

      Still funny to me they have batteries rated at 48V but, ummm… 240V 🤷‍♂️

        • No1@aussie.zone
          link
          fedilink
          arrow-up
          2
          arrow-down
          3
          ·
          edit-2
          11 months ago

          Yeah, but does that mean a 48V 5.12kWh would be (roughly) equivalent to a 240V 1 kWh battery?

          Sorry, I’m only kinda familiar with power tools and bikes etc where the motor/output is rated the same as the battery itself…

          meh, I guess the volts don’t matter. All the other batteries are rated at Ah, not kWh…

          • ⸻ Ban DHMO 🇦🇺 ⸻@aussie.zoneM
            link
            fedilink
            arrow-up
            11
            ·
            edit-2
            11 months ago

            5.12kW is 5.12kW no matter what the voltage is. I think you might be confusing current (amps) with power (watts).

            P = IV

            P = power

            I = current

            V = potential difference (voltage)

            so 5.12*10^3 W / 240V = 2133.33A —> 2.13 kAh

            vs

            5.12*10^3 W / 48V = 10666.67A —> 10.67 kAh

            so yes, it will last longer at 48V but calling it 5.12kWh is not misleading

            • No1@aussie.zone
              link
              fedilink
              arrow-up
              8
              ·
              11 months ago

              Yeah, thanks. I kinda figured it out that I was confusing the other batteries being rated at Ah, not kWh.

              But I appreciate you spending the time to set it out clearly.

              Have a good one.

        • No1@aussie.zone
          link
          fedilink
          arrow-up
          10
          ·
          edit-2
          11 months ago

          Thanks, bro. That’s a great comment to encourage participation.

          I’d hate to learn anything. And your comment achieved that.

          Have an upvote and hope you have a great day!

    • Yendor@reddthat.com
      link
      fedilink
      arrow-up
      2
      ·
      11 months ago

      48V DC is the standard voltage in a bunch of industrial applications. At work I’ve installed sites with over 300kWh of storage, all at 48VDC. Back in the day it was strings of 24x 2V lead-acid batteries. Recently the industry is moving towards cells with 14x - 16x lithium cells, depending on the exact lithium chemistry.

      You need an inverter to go from DC to AC anyway, changing the voltage at the same time doesn’t add much to the complexity. Some systems use 400V, but the actually batteries those systems use are usually 8x 48V batteries connected in series.