Why would this happen? Should I try replacing the wire nut and turning it back on or is there something deeper going on? Thanks for any tips!

  • P00Pchute@lemmy.world
    link
    fedilink
    arrow-up
    17
    ·
    edit-2
    11 months ago

    This is more of an electrical problem rather than a plumbing issue. But rust inside the junction box is a sign of water getting into it. You need to find the source of the water that’s getting in and stop that too. It looks like there is only a bad connection inside the wire nut. Most likely due to being wet. You can try changing the wire nuts if you feel comfortable with electricity.

    1. Switch the breaker to “off” and lock it out & tag it so nobody turns it on accidently.

    2. Verify power is off to both wires with a meter or voltage indicator.

    3. Cut back the wires until you have a good section of wire to strip and install new wire nuts. (Remove one wire nut at a time so you don’t mix wires.)

    If you are not comfortable with electricity please do not attempt this repair and contact someone who is.

    • mystik@lemmy.world
      link
      fedilink
      arrow-up
      2
      ·
      11 months ago

      The rust and/or bad connection will create resistance at the connection, which can cause it to heat up as well. If that’s what happened, it could have melted the wire nut slowly till the wire was exposed, and shorted against a metal part. It looks like there is a diagram of the wiring too to the left near that connection too, which may help if you need to disconnect/reconnect it.

    • kjpctech@lemmy.worldOP
      link
      fedilink
      arrow-up
      1
      ·
      11 months ago

      I’m confused if this is a plumbing or electrical thing. Would the short be in the water heater or in the wire before it?

      • Aussiemandeus @lemmy.world
        link
        fedilink
        arrow-up
        3
        ·
        11 months ago

        Either way it’s an electrical short.

        It is probably in the heater its self but you don’t want to go playing with electricity if you don’t know what you’re doing because best you can easily kill yourself or burn your house down

  • stevestevesteve@lemmy.world
    link
    fedilink
    arrow-up
    5
    ·
    11 months ago

    All I can tell from that photo is that the wire nut has overheated and at a minimum the wire nut needs to be replaced. More may need to be done depending on why it overheated. If it was simply a poor install of the nut to begin with, replacement may be all that’s needed. If there is something else going on causing high current draw hence overheating, you’ll need to troubleshoot that too

  • Rognaut@lemmy.world
    link
    fedilink
    English
    arrow-up
    5
    arrow-down
    1
    ·
    11 months ago

    You have what is called an electrical short to ground.

    You need a professional.

    This is caused by excessive current traveling straight to ground. Which in turn causes the point of highest resistance to become very hot. Which in turn increases the resistance of that point in a sort of runaway effect of increasing heat and resistance. Until you reached the flash point of the material.

    Changing the wire nut will not solve the problem. It was only an indication of a problem.

  • kjpctech@lemmy.worldOP
    link
    fedilink
    arrow-up
    1
    ·
    11 months ago

    Thanks all who replied. I ended up investigating some more and noted that the wires inside the nut that melted were barely connected. I checked the elements resistance in the water heater and visually checked the electrical wire going to the breaker box. Everything looks clean with no indication of an issue besides that wire nut. I’m concluding it was a loose connection and hoping that is right. I redid the connection and installed a fire alarm right above the water heater. I then let the water completely warm up and checked the wires (after turning off power) to make sure they were not hot. So far it is all working as expected.

    • P00Pchute@lemmy.world
      link
      fedilink
      arrow-up
      2
      ·
      11 months ago

      Great work. Now just keep an eye on it to see what was causing the moisture or water to get inside the electrical connection to cause it to rust inside. May be a leaking connection or valve. Happy new year.