I’m currently looking into various DC DC converters and was confused that the Meanwell DDR-60 series only shows a typical rating but says nothing about the efficiency at idle. From AC/DC converters I’m used to have a curve that starts at idle and maybe 70% and goes to 100% load, having the peak at ninetee something.

(Edit: link goes directly to the PDF)

  • HewlettHackard
    link
    fedilink
    English
    arrow-up
    6
    ·
    edit-2
    1 year ago

    It’s similar to AC-DC. From a simplistic perspective, efficiency at idle will be 0% because the converter itself still uses some power, then efficiency increases with load since the converter overhead becomes less significant as the useful work increases. Googling “dc dc converter efficiency curve” gives plenty of results.

      • pneumapunk@lemmy.sdf.org
        link
        fedilink
        English
        arrow-up
        3
        ·
        1 year ago

        They might be willing to spec it as “quiescent current” (current drawn at 0 load) even if they don’t provide a full curve. Annoying that it’s not on the datasheet.

  • SomeoneSomewhere@lemmy.nz
    link
    fedilink
    English
    arrow-up
    2
    ·
    1 year ago

    Even on the equipment where you do get a graph of efficiency vs load, the line usually only starts at 10% load - that’s where your 70% efficiency figure is for.