Hi, I have built a microvawe transformer spotwelder, I have put a single turn of welder wire for in the secondary and I’m timing it with arduino. Worth mentioning it was/is a 230V transformer. Electrodes are sharpened copper rods. I believe the voltage is still high. The spotwelds it produces are slightly discolored and not as strong as you would expect. Is this design fundamentally borked? Is there anything else I can make to make it better? Photo from test stage before it was built into a project box, it is less “shocking” now.

  • Darkassassin07
    link
    fedilink
    English
    arrow-up
    2
    ·
    9 months ago

    You need to go up in voltage, not down.

    Try it on 240v. (check your 5v supply can handle that, or power it separately)

    • dansity@lemmy.dbzer0.comOP
      link
      fedilink
      English
      arrow-up
      1
      ·
      8 months ago

      I have 230V or 400V three phase. I live in the EU. So this cannot be solved without replacing the winding on the transformer I guess.

      • BigDanishGuy@sh.itjust.works
        link
        fedilink
        English
        arrow-up
        1
        ·
        8 months ago

        If it’s just a matter of getting a larger voltage, then you already got 400V. No need for new windings, unless the insulation on the primary can’t handle 400V.

      • SomeoneSomewhere@lemmy.nz
        link
        fedilink
        English
        arrow-up
        1
        ·
        8 months ago

        If you have a 230V supply and a 230V transformer, you are fine. I believe they thought you were using a 120V supply on a 230V transformer.

        Raising the input voltage will probably not get you what you want.