I’m syncoiding from my normal RAIDz2 to a backup mirror made of 2 disks. I looked at zpool iostat and I noticed that one of the disks consistently shows less than half the write IOPS of the other:

                                        capacity     operations     bandwidth 
pool                                  alloc   free   read  write   read  write
------------------------------------  -----  -----  -----  -----  -----  -----
storage-volume-backup                 5.03T  11.3T      0    867      0   330M
  mirror-0                            5.03T  11.3T      0    867      0   330M
    wwn-0x5000c500e8736faf                -      -      0    212      0   164M
    wwn-0x5000c500e8737337                -      -      0    654      0   165M

This is also evident in iostat:

     f/s f_await  aqu-sz  %util Device
    0.00    0.00    3.48  46.2% sda
    0.00    0.00    8.10  99.7% sdb

The difference is also evident in the temperatures of the disks. The busier disk is 4 degrees warmer than the other. The disks are identical on paper and bought at the same time.

Is this behaviour expected?

  • lightrushOP
    link
    fedilink
    English
    arrow-up
    1
    ·
    edit-2
    8 days ago

    Iiinteresting. I’m on the larger AB350-Gaming 3 and it’s got REV: 1.0 printed on it. No problems with the 5950X so far. 🤐 Either sheer luck or there could have been updated units before they officially changed the rev marking.