This is on the fridge at work today.

  • Neato@ttrpg.network
    link
    fedilink
    English
    arrow-up
    22
    ·
    8 months ago

    I’m trying to figure out what kind of defect would cause that. The heating elements of a fridge, the air exchange that has the hotter refrigerant, are all outside the box I believe. If the compressor fails, the refrigerant doesn’t move and doesn’t move heat. So it’d just be an insulated box, right? I think that’d get hotter an ambient but I’m not sure I’d say it’s “heating”.

    • moody@lemmings.world
      link
      fedilink
      arrow-up
      37
      ·
      8 months ago

      If the compressor dies but the evaporator tray is still heating, it would definitely cause the fridge to warm up.

    • marcos@lemmy.world
      link
      fedilink
      arrow-up
      8
      ·
      8 months ago

      Some malfunction on the control of defrosting. Or maybe it’s powered by Peltier elements.

      • gnate@lemmy.world
        link
        fedilink
        English
        arrow-up
        2
        ·
        8 months ago

        Thermoelectric was my first thought, since it can heat or cool, to maintain a set point, warm food, or chill beverages, as implemented in some fancy lunch boxes. I didn’t know if the same applies at this scale, but I’m assuming this unit uses a compressor.

        • marcos@lemmy.world
          link
          fedilink
          arrow-up
          3
          ·
          8 months ago

          Something of this size should absolutely use a compressor.

          But there’s a difference between “should” and “does”, and the fact that failed into heating changes that expectation a lot.

    • usualsuspect191
      link
      fedilink
      arrow-up
      5
      ·
      8 months ago

      I’ve seen this happen when the condenser coil is outside and during electrical work to the building the phases were swapped so the unit essentially ran in reverse.

      • Revan343
        link
        fedilink
        arrow-up
        4
        ·
        8 months ago

        That can only happen on 3 phase though, which a small fridge generally is not

        • usualsuspect191
          link
          fedilink
          arrow-up
          6
          ·
          8 months ago

          Correct. The picture is not great, but you can see the racking that implies there’s at least one other door so this could be a larger commercial fridge running 3 phase

          • Revan343
            link
            fedilink
            arrow-up
            2
            ·
            8 months ago

            Oh yeah, looking closer I think you’re right

      • Neato@ttrpg.network
        link
        fedilink
        English
        arrow-up
        2
        ·
        8 months ago

        Yep. But you can just install a valve for the refrigerant and that’s how you get a selectable heat pump.